Equipment Name:
  • VOCs Recovering System
Removal efficiency:
  • VOCs: 95~99%
  • Odor: -----
  • Particles: -----
  • Dust and oil: -----
  • Fumes: -----
Recommended for:
  • Airflow is between 0.15~0.5Nm3/min
  • High recycle value solvent

Feature

1. Flow Chart of VOCs Recovering System

A. Solvents vapor is sucked from the washing machine in high density and low suction.
B. Solvents vapor is condensed in Pre-cooled condenser used low temperature air from the super cooling condenser.
C. The condensed solvent vapor is compressed by a compressor.                   
D. The compressed solvent vapor is liquefied in Water cooled condenser.
E. The compressed solvent vapor is almost liquefied in water cooled condenser.
F-1. The un-condensed vapor is adsorbed by active carbon unit.
F-2. The solvent vapor adsorbed by the active carbon is desorbed by heating and vacuum. 
G. The condensed liquid is periodically conveyed to the condensed liquid storage tank.
H. The condensed liquid is conveyed to water separator from the condensed liquid storage tank and then back to the cleaning machine.

2. Recovering Various Kinds of VOCs

  • Recover halogenated hydrocarbon solvents.
  • Easily modify if solvent is changed.
  • Type of recovering organic solvent: 
Organic Solvent Name Boiling Point
111-trichloreoethane 74
R113 47.7
Trichloroethene 87.2
Dichloroethane 40.2
Perclene 121
Hydrochlorofluorocarbons-225 54
1-Bromopropane 71
Vertrel
55
HFE-7100 61
HFE-7200 76
Methanol 64.7

Organic Solvent Name Type Customer Performance
111-trichloreoethane S Series V
R113 S Series V
Trichloroethene S Series V
Dichloroethane S Series V
Perclene S Series V
Hydrochlorofluorocarbons-225 S Series V
1-Bromopropane S Series V
Vertrel
S Series
V
HFE-7100 S Series V
HFE-7200 S Series V
Methanol S Series V

Advantages

1. High Economical Benefit after installed:
  • VOC Recovering Systems can realize high rate of solvents recovery
  • A large quantity of use will be cut.
  • Recycled solvent can be used directly.
  • Running cost is very cheap.
*

2. Wide Application Field




Recovering Organic Solvent Type:
No Industry Field Projects
1 Consumer Electronics and Components of Mechanical Equipment 204
2 Precision Mechanical Manufacturing Industry 151
3 Medical Appliances Manufacturing 32
4 Automobile and Parts Manufacturing 103
5 Chemical Industries 22
6 Waste Gas Treatment Factory 9
7 Other Industries 19

Specification

1. Equipment Specification:
  CGR-S150
Flow Rate 150L / min
Exhaust Less than 100ppm
Electronic Consumption 3phase 220V 1.9kW
Cooling Water 10L / min
Cooling Water Temprature 7~25℃
Cooling Water Pope 20A
Operation Pressure 4.4~5.4 kg/cm2
Installation Condition Location: Indoor
Ambient temperature: 5~35℃
Dimension Size (mm) W1,650 x D580 x H1,622
Weight 500kg
  CGR-S250
Flow Rate 250L / min
Exhaust Less than 100ppm
Electronic Consumption 3phase 220V 3.0kW
Cooling Water 15L / min
Cooling Water Temprature 7~25℃
Cooling Water Pope 25A
Operation Pressure 4.4~5.4 kg/cm2
Installation Condition Location: Indoor
Ambient temperature: 5~35℃
Dimension Size (mm) W1,855 x D730 x H1,881
Weight 810kg
  CGR-S500
Flow Rate 500L / min
Exhaust Less than 100ppm
Electronic Consumption 3phase 220V 5.5kW
Cooling Water 25L / min
Cooling Water Temprature 7~25℃
Cooling Water Pope 25A
Operation Pressure 4.4~5.4 kg/cm2
Installation Condition Location: Indoor
Ambient temperature: 5~35℃
Dimension Size (mm) W2,080 x D730 x H1,881
Weight 1,040kg

2. Installation Diagram: 

 
Industry Mechanical equipment manufacture for transport
Equipment Washing facilities (around-single-slot automatic washing machine) 
Exhaust Name Trichloroethylene
Situation The volatile gas emitted from the washing apparatus, and diffusion of the gas into the groove.
Displacement 2.5 ton(Emission exhaust 1.8 ton/month)
Operation Time 24hours/day, 22days/month
Purpose Conform to Taiwan environmental protection standard
Before Installed Emission: 725ppm
Usage: 2.5 ton/month
After Installed
Emission: 15ppm
Usage: 0.85 ton/month
Reduction Rate Reduce66%